GB/T 6728-2017 结构用冷弯空心型钢
方管与矩管
外方内方,四角有圆弧。栏杆、货架、幕墙龙骨、光伏支架的主力材料,规格以「边长×边长×壁厚」表示。
理论米重表
下表为现行国标的理论值。截面面积由米重反算(A = W × 10 ÷ 7.85),6 m 与 12 m 支重为直接乘积,用于快速估算吊装与运输。
| 规格 | 理论米重 kg/m | 截面面积 cm² | 6 m 支重 kg | 12 m 支重 kg |
|---|---|---|---|---|
| 20×20×1.5 | 0.871 | 1.11 | 5.2 | 10.5 |
| 20×20×2.0 | 1.130 | 1.44 | 6.8 | 13.6 |
| 20×20×3.0 | 1.601 | 2.04 | 9.6 | 19.2 |
| 20×20×4.0 | 2.010 | 2.56 | 12.1 | 24.1 |
| 25×25×1.5 | 1.107 | 1.41 | 6.6 | 13.3 |
| 25×25×2.0 | 1.444 | 1.84 | 8.7 | 17.3 |
| 25×25×3.0 | 2.072 | 2.64 | 12.4 | 24.9 |
| 25×25×4.0 | 2.638 | 3.36 | 15.8 | 31.7 |
| 30×30×1.5 | 1.342 | 1.71 | 8.1 | 16.1 |
| 30×30×2.0 | 1.758 | 2.24 | 10.6 | 21.1 |
| 30×30×3.0 | 2.543 | 3.24 | 15.3 | 30.5 |
| 30×30×4.0 | 3.266 | 4.16 | 19.6 | 39.2 |
| 40×40×1.5 | 1.813 | 2.31 | 10.9 | 21.8 |
| 40×40×2.0 | 2.386 | 3.04 | 14.3 | 28.6 |
| 40×40×3.0 | 3.485 | 4.44 | 20.9 | 41.8 |
| 40×40×4.0 | 4.522 | 5.76 | 27.1 | 54.3 |
| 50×50×1.5 | 2.284 | 2.91 | 13.7 | 27.4 |
| 50×50×2.0 | 3.014 | 3.84 | 18.1 | 36.2 |
| 50×50×3.0 | 4.427 | 5.64 | 26.6 | 53.1 |
| 50×50×4.0 | 5.778 | 7.36 | 34.7 | 69.3 |
| 60×60×1.5 | 2.755 | 3.51 | 16.5 | 33.1 |
| 60×60×2.0 | 3.642 | 4.64 | 21.9 | 43.7 |
| 60×60×3.0 | 5.369 | 6.84 | 32.2 | 64.4 |
| 60×60×4.0 | 7.034 | 8.96 | 42.2 | 84.4 |
| 80×80×1.5 | 3.697 | 4.71 | 22.2 | 44.4 |
| 80×80×2.0 | 4.898 | 6.24 | 29.4 | 58.8 |
| 80×80×3.0 | 7.253 | 9.24 | 43.5 | 87.0 |
| 80×80×4.0 | 9.546 | 12.16 | 57.3 | 114.5 |
| 100×100×1.5 | 4.639 | 5.91 | 27.8 | 55.7 |
| 100×100×2.0 | 6.154 | 7.84 | 36.9 | 73.9 |
| 100×100×3.0 | 9.137 | 11.64 | 54.8 | 109.6 |
| 100×100×4.0 | 12.058 | 15.36 | 72.3 | 144.7 |
| 120×120×1.5 | 5.581 | 7.11 | 33.5 | 67.0 |
| 120×120×2.0 | 7.410 | 9.44 | 44.5 | 88.9 |
| 120×120×3.0 | 11.021 | 14.04 | 66.1 | 132.3 |
| 120×120×4.0 | 14.570 | 18.56 | 87.4 | 174.8 |
| 150×150×1.5 | 6.994 | 8.91 | 42.0 | 83.9 |
| 150×150×2.0 | 9.294 | 11.84 | 55.8 | 111.5 |
| 150×150×3.0 | 13.847 | 17.64 | 83.1 | 166.2 |
| 150×150×4.0 | 18.338 | 23.36 | 110.0 | 220.1 |
| 200×200×1.5 | 9.349 | 11.91 | 56.1 | 112.2 |
| 200×200×2.0 | 12.434 | 15.84 | 74.6 | 149.2 |
| 200×200×3.0 | 18.557 | 23.64 | 111.3 | 222.7 |
| 200×200×4.0 | 24.618 | 31.36 | 147.7 | 295.4 |
| 40×20×1.5 | 1.342 | 1.71 | 8.1 | 16.1 |
| 40×20×2.0 | 1.758 | 2.24 | 10.6 | 21.1 |
| 40×20×3.0 | 2.543 | 3.24 | 15.3 | 30.5 |
| 50×25×1.5 | 1.696 | 2.16 | 10.2 | 20.3 |
| 50×25×2.0 | 2.229 | 2.84 | 13.4 | 26.8 |
| 50×25×3.0 | 3.250 | 4.14 | 19.5 | 39.0 |
| 60×40×1.5 | 2.284 | 2.91 | 13.7 | 27.4 |
| 60×40×2.0 | 3.014 | 3.84 | 18.1 | 36.2 |
| 60×40×3.0 | 4.427 | 5.64 | 26.6 | 53.1 |
| 80×40×1.5 | 2.755 | 3.51 | 16.5 | 33.1 |
| 80×40×2.0 | 3.642 | 4.64 | 21.9 | 43.7 |
| 80×40×3.0 | 5.369 | 6.84 | 32.2 | 64.4 |
| 100×50×1.5 | 3.462 | 4.41 | 20.8 | 41.5 |
| 100×50×2.0 | 4.584 | 5.84 | 27.5 | 55.0 |
| 100×50×3.0 | 6.782 | 8.64 | 40.7 | 81.4 |
| 120×60×1.5 | 4.168 | 5.31 | 25.0 | 50.0 |
| 120×60×2.0 | 5.526 | 7.04 | 33.2 | 66.3 |
| 120×60×3.0 | 8.195 | 10.44 | 49.2 | 98.3 |
| 150×100×1.5 | 5.817 | 7.41 | 34.9 | 69.8 |
| 150×100×2.0 | 7.724 | 9.84 | 46.3 | 92.7 |
| 150×100×3.0 | 11.492 | 14.64 | 69.0 | 137.9 |
| 200×100×1.5 | 6.994 | 8.91 | 42.0 | 83.9 |
| 200×100×2.0 | 9.294 | 11.84 | 55.8 | 111.5 |
| 200×100×3.0 | 13.847 | 17.64 | 83.1 | 166.2 |
计算式
W = 4 × (a − t) × t × 7.85 ÷ 1000 (方管,a 边长 mm,t 壁厚 mm)
W = 2 × (a + b − 2t) × t × 7.85 ÷ 1000 (矩管)
W = 2 × (a + b − 2t) × t × 7.85 ÷ 1000 (矩管)
选型要点
- 方管的壁厚公差是关键:标称 2.0 mm 实测 1.7 mm 很常见,按理论重量买会吃亏,按过磅买要加价。
- 冷弯方管的四角有圆角,圆角半径一般为壁厚的 1.5~2.5 倍,做插入式连接件时要留这个间隙。
- 同米重下方管抗扭远好于角钢拼焊,做需要抗扭的构件(如桁架端部、栏杆立柱)优先方管。
- 热镀锌方管要在成形后镀,先镀后切的切口必须做富锌漆修补,否则切口是最先锈的地方。
采购与加工
下单时写清「品种 + 规格 + 牌号 + 质量等级 + 定尺 + 公差组别」,四项少一项都可能拿到不是你要的料。方管与矩管 的公差按 GB/T 6728-2017 结构用冷弯空心型钢 的规定分组,重要结构要指定更严的那一组。
米重与实重:本表数值为理论重量,按 7.85 g/cm³ 计算。实际过磅值与表值通常有 −2%~−5% 的差异(负公差),
按理论重量结算时这部分由买方承担;按过磅结算则卖方会加价 2%–4%。两种方式都可以,但必须在合同里写清是哪一种。